site stats

Buford complex variant

WebNov 24, 2024 · The Buford complex represents another anatomic variant and is described as a cordlike thickening of the middle glenohumeral ligament and absence of the anterosuperior labrum. This anatomic … WebApr 2, 2012 · A Buford complex is a congenital labral variant. The anterosuperior labrum is absent in the 1-3 o'clock position and the middle glenohumeral ligament is usually thickened. It is present in …

Isolated tear of the cord-like middle glenohumeral ligament in Buford …

WebA Buford complex is a normal anatomical labral variant where the anterior labrum is absent and the middle glenohumeral ligament is “cord-like” in structure. This case … Webcomplex ratherthananavulsed labrum. Thisnormalvariation maybemistaken fora detached labrum. AJR1996;166:869-873 ... features oftheBufordcomplex anditscapsulolabral variant. Materials andMethods ... Fig.1.-Buford complex. … hagood coxe rice plantation https://shekenlashout.com

A Buford Complex in a Division I Collegiate American Football Player

WebDec 19, 2012 · This complex is known as a Buford complex and was actually described by myself in The Journal of Arthroscopy. The point of that study was to not repair what was, and is, a normal anatomic variant of the cord-like middle glenohumeral ligament. The intraarticular subscapularis did have some partial tear of approximately 5% that was … WebThe Buford complex The Buford Complex is an anatomical variant of the anterosuperior shoulder anatomy. It was first described by Williams et al who discovered that in some shoulders, an absent anterosuperior … WebOf the 84 specimens, 15 (17.9%) manifested a cord-like MGHL, and one (1.2%) the Buford complex. None of the specimens had a sublabral foramen, a finding that requires further investigation. Conclusions: Our results suggest that the Buford complex is a rare variant of the GHLC, and the cord-like MGHL appears to be a relatively common normal variant. branch manifest

Buford complex shoulder HealthTap Online Doctor

Category:The Buford complex--the "cord-like" middle …

Tags:Buford complex variant

Buford complex variant

Sublabral Foramen and Buford Complex: Inferior Extent of the …

WebSep 18, 2024 · The anterosuperior labrum may also be diminutive or absent. The combination of an absent anterosuperior labrum and a thickened cordlike MGHL is termed the Buford complex; this is a relatively uncommon normal variant, occurring in approximately 1.5% of patients ( Fig. 7 ). This variant is important to recognize because …

Buford complex variant

Did you know?

WebThe Buford complex (27a) is an anatomic variant that is seen anterosuperiorly, when the anterosuperior portion of the labrum is absent and the middle glenohumeral ligament is thick and cordlike. 18 . 27 . Figure 27: An axial fat suppressed T1-weighted MR arthrogram of a Buford complex. Note absence of the anterior superior labrum (arrowhead ... Webnormal variant . the labrum attached to the glenoid rim and a flat/broad middle glenohumeral ligament is the most common “normal” variation. ... Buford complex (absent anterosuperior labrum + cordlike MGHL) seen …

WebApr 1, 2002 · PURPOSE: To determine the inferiormost extent of the anterosuperior labral variants on conventional transverse MR images. MATERIALS AND METHODS: We reviewed transverse MR images in 50 consecutive patients with a sublabral foramen or Buford complex at arthroscopy. RESULTS: The sensitivity of MR for diagnosing a … WebBackground: Although middle glenohumeral ligament (MGHL) variations have been shown in the literature, their clinical effect and relationship with intra-articular pathologies have yet to be revealed, except for the Buford complex. This study was designed to classify MGHL and to reveal its relationship with clinical pathologies. Methods: A total of 843 …

WebSep 7, 2024 · 1 Introduction. The middle glenohumeral ligament (MGHL) has the greatest variation in its shape and size among all the ligaments of the shoulder joint. The Buford complex, a kind of normal anatomic variant, has been defined as the combination of the absence of the anterior superior labrum and the presence of a cord-like MGHL, which … WebA Buford complex is a normal anatomic variant where the anterosuperior labrum is absent from the 1 to 3 o'clock position and there is a cord-like thickened m...

WebBuford Complex: No, a buford complex is a normal variant. It is a thickening of a ligament in the shoulder to a cord like appearance. Created for people with ongoing healthcare …

http://clinical-mri.com/buford-complex/ branch manorWebMay 1, 1996 · The adjacent portions of the superior and antero-inferior labrum are normal [35]. It is important for the radiologist to be aware of this anatomic variant because: a. in imaging exams, a thickened ... branch manifoldWebTwo normal variants occur in superior portion of the anterior labrum:. Sublabral Foramen (also called Sublabral Hole), The Buford complex. branch m and t banks hours orchard park nyWebFeb 29, 2016 · Doctor of Medicine (M.D.)Medicine. 1983 - 1987. Activities and Societies: Dean's Award for Academic Excellence 1984-1985, Year 2 medical school Curriculum Committee 1985-1986, Alpha Omega Alpha ... branch martWebThe Buford complex has previously been thought to be a normal anatomic variant with minimal clinical significance. The purpose of this study was to determine a potential … hagood flooring canton txWebBuford Complex: A "Buford Complex" refers to a normal anatomic variant to the superolabral complex of the shoulder, seen in about 1.5% of individuals. The middle … branch master doesn\u0027t exist in remote originWebBuford complex. Superior labral anterior posterior tear. State-of-the-Art Development of Complex Systems and Their Simulation Methods. Yiming Tang et al., Complex System Modeling and Simulation, 2024. Crowd intelligence evolution based on complex network. Jianran Liu et al., International Journal of Crowd Science, 2024. branch manual